Resource environments model device-local physics: batteries, renewables, EVs, flexible loads, diesel generators, and data centers.

In plain language, this layer answers a simple question: if we control one device by itself, or attach many such devices to a grid, how does that device update its own power, energy, or internal state?

The most important distinction is:

  • standalone Env: use this when you want to study one device on its own
  • Bundle: use this when you want to attach many devices to a grid / market / microgrid env

Why keep standalone resource envs at all?

They are usually not the final system-level benchmark. Their main job is to serve as device-level experiment benches: validating local physics, providing the smallest possible RL example, debugging training pipelines, and testing whether a controller can learn a simple objective before we couple the same resource to a larger grid. In contrast, the more system-level questions in this repo, such as voltage regulation, branch congestion, losses, and network safety, usually appear only after bundles are attached to a parent distribution, transmission, or market env.

So a practical rule of thumb is:

  • choose a standalone Env when you want the cleanest possible single-device experiment or training example
  • choose a Bundle plus a parent env when you care about system interactions and benchmark-style power-system behavior

Not every resource exposes both forms. The current public surface is:

Resource Standalone env Bundle Typical use
Battery BatteryEnv BatteryBundle standalone storage tests; grid / market attachment
Renewable RenewableEnv / SolarEnv / WindEnv RenewableBundle standalone generator tests; grid attachment
Vehicle VehicleEnv no public bundle standalone EV scheduling
Flexible load FlexLoadEnv FlexLoadBundle standalone demand response; DSO / DERs
Diesel no standalone env DieselBundle grid / microgrid attachment
Data center DataCenterEnv no public bundle standalone load-side scheduling / thermal control

This page summarizes the physics of each resource type. For symbol-level signatures see API → Resources.

Sign conventions

  • Active power P > 0 means injection to the grid.
  • For batteries and EVs: discharge is positive, charge is negative.
  • For flexible loads: positive current_p_mw means load reduction (curtail or shift-out); negative means a load increase from releasing deferred demand.
  • For diesel: active power is non-negative and injects into the host env.
  • For data centers: current_p_mw is always negative because the data center is always a net load.

Battery — BatteryEnv and BatteryBundle

The battery model is shared between standalone and bundle form.

Feasible-power clipping

Feasible grid-side power is clipped by both converter rating and SOC headroom:

\[ P_{\max}^{\text{dis}} = \min\!\left(P_{\text{rated}},\ \frac{(\mathrm{SOC} - \mathrm{SOC}_{\min})\, E_{\max}\, \eta_d}{\Delta t}\right) \]
\[ P_{\max}^{\text{chg}} = \min\!\left(P_{\text{rated}},\ \frac{(\mathrm{SOC}_{\max} - \mathrm{SOC})\, E_{\max}}{\eta_c\, \Delta t}\right) \]

\(E_{\max}\) is capacity_mwh; \(\eta_c\) and \(\eta_d\) are one-way charge / discharge efficiencies; \(\Delta t\) is delta_t_hours.

SOC update

\[ \Delta \text{soc} = \begin{cases} - \dfrac{P\, \Delta t}{\eta_d\, E_{\max}} & P \ge 0 \quad \text{(discharge)} \\[6pt] - \dfrac{P\, \Delta t\, \eta_c}{E_{\max}} & P < 0 \quad \text{(charge)} \end{cases} \]

Standalone BatteryEnv

The standalone battery has no device-local economic reward:

\[ r_t = 0 \]

Its CMDP cost channel is

\[ \text{costs} = (C_{\text{cycle}},) \]

with

\[ C_{\text{cycle}} = c_{\text{cycle}}\, |P|\, \Delta t \]

where \(c_{\text{cycle}}\) corresponds to cycle_cost_per_mwh in the implementation. info["cost_sum"] is the sum of the reported cost components. Separately, info["cost_action_clip"] is a clipping diagnostic and is not folded into the CMDP cost vector.

Cost channel definitions:

Symbol Constraint name Info key Meaning
\(C_{\text{cycle}}\) cycle_throughput cost_cycle_throughput Battery throughput cost (
diagnostic N/A cost_action_clip Normalized distance between requested and feasible battery power; reported in info but not included in the CMDP cost vector.

BatteryBundle

BatteryBundle is the public bundle implementation used by grid and market envs. It packs n_devices batteries into batched per-device arrays and supports optional reactive power. With enable_q_control=True, reactive power is clipped by the apparent-power limit after active power is finalized:

\[ |Q| \le \sqrt{S_{\text{rated}}^2 - P^2} \]

BatteryBundle.step reports cost_soc_clip and cost_cycle diagnostics. Unlike standalone BatteryEnv, the current bundle path does not expose a cost_sum key, so parent grid envs that aggregate only cost_sum / cost do not automatically include these battery diagnostics in info["cost_resource"]. Market envs currently ignore bundle cost channels by design.

Observation rebuild gap

Notation in this section: \(p\) is active power (MW), \(q\) is reactive power (MVAR).

BatteryBundle.step computes the current feasible \(p\) / \(q\) and writes them into the returned obs_slice. The parent env, however, then rebuilds the bundle observation via observe(state, ctx). Because BatteryBundleState currently stores SOC only, parent observations expose SOC plus zeroed \(p\) / \(q\) channels, not the just-applied power. The agent therefore cannot directly see how its commanded power was clipped — it has to infer that indirectly from SOC changes.

Renewable — RenewableEnv, SolarEnv, WindEnv, RenewableBundle

RenewableEnv is a profile-driven generator. SolarEnv and WindEnv are convenience subclasses with different default capacity-factor profiles; they do not define separate physics.

Action and output

The action a in [-1, 1] maps to curtailment:

\[ \text{curtailment}_t = \frac{1 - a_t}{2} \]

so a = +1 means no curtailment, and a = -1 means full curtailment. Active power output is then:

\[ P_t = P_{\text{cap}}\, \mathrm{CF}(t)\, (1 - c_t) \]

CF(t) is the time-indexed capacity-factor profile. If allow_curtailment=False, curtailment is forced to zero. With enable_q_control=True, reactive power is clipped by the same apparent-power limit used by the battery bundle.

Reward and cost

The standalone renewable env also uses zero scalar reward:

\[ r_t = 0 \]

Its CMDP cost channel is

\[ \text{costs} = (C_{\text{curtail}}, C_{\text{q-clip}}) \]

where \(C_{\text{curtail}}\) is non-zero when the agent curtails available renewable output, and \(C_{\text{q-clip}}\) is non-zero when requested reactive power is clipped by the apparent-power limit.

Cost channel definitions:

Symbol Constraint name Info key Meaning
\(C_{\text{curtail}}\) curtailment cost_curtailment Curtailed available renewable power/energy; standalone env uses a lost-capacity proxy, bundle mode uses configured curtailment cost.
\(C_{\text{q-clip}}\) q_clip cost_q_clip Normalized amount by which requested reactive power is clipped by the apparent-power limit.

Device-local renewable envs do not carry voltage / thermal constraint costs; those come from the parent grid env. RenewableBundle follows the same protocol and packs n_devices PV / wind plants into batched per-device arrays.

Vehicle — VehicleEnv

VehicleEnv adds temporal availability and trip energy consumption on top of a battery-like SOC model.

State extension

classDiagram
    class VehicleState {
        +soc
        +is_home
        +time_of_day
        +done
    }
    class VehicleParams {
        +capacity_mwh
        +soc_departure_min
        +p_charge_max_mw
        +p_discharge_max_mw
        +trip_departures
        +trip_arrivals
        +trip_energies
    }

State-transition order

  1. Check departures and arrivals using fixed-size trip arrays.
  2. On departure, subtract trip_energy from SOC and record any shortfall relative to soc_departure_min.
  3. Apply charging or vehicle-to-grid discharge only if the vehicle is at home (is_home=1).
  4. Advance time of day.

Action

Asymmetric scaling:

  • a > 0: V2G discharge up to p_discharge_max_mw
  • a < 0: charging up to p_charge_max_mw

SOC update follows the same one-way-efficiency rule as the battery, but charge / discharge is forced to zero when is_home=0.

Reward and cost

The standalone EV env uses

\[ r_t = 0 \]

and a single CMDP cost channel

\[ \text{costs} = \left(\max(0,\ \mathrm{SOC}_{\text{dep,min}} - \mathrm{SOC}_{\text{at dep}}),\right) \]

This term is non-zero only on the step where the vehicle departs below the required SOC.

Cost channel definition:

Symbol Constraint name Info key Meaning
\(C_{\text{dep}}\) departure_soc cost_departure_soc SOC shortfall below the required departure SOC, reported only on departure steps.

Flexible load — FlexLoadEnv and FlexLoadBundle

FlexLoadEnv models demand response with two controls: curtail now and shift demand out now, to be released later.

Step order

flowchart TD
    POP["1. pop deferred-demand ring buffer<br/>shift_in_mw"]
    PARSE["2. parse action -> curtail_mw, shift_out_mw"]
    CLIP["3. clip by curtail_cap_mw, shift_cap_mw"]
    SPREAD["4. spread shift_out_mw over next shift_horizon slots"]
    NET["5. net injection<br/>P = P_curtail + P_shift_out - P_shift_in"]
    POP --> PARSE --> CLIP --> SPREAD --> NET

Sign convention

\[ \Delta P = P_{\text{curtail}} + P_{\text{shift out}} - P_{\text{shift in}} \]
  • positive current_p_mw: load reduction
  • negative current_p_mw: load increase from releasing deferred demand

Reward and cost

The standalone flex-load env uses

\[ r_t = 0 \]

and

\[ \text{costs} = (C_{\text{curtail}}, C_{\text{shift}}, C_{\text{simul}}) \]

with:

  • \(C_{\text{curtail}} = c_{\text{curtail}}\, P_{\text{curtail}}\, \Delta t\)
  • \(C_{\text{shift}}\): a per-step discomfort penalty proportional to buffered deferred energy
  • \(C_{\text{simul}}\): a penalty when curtailment and shifting are both activated in the same step

In the implementation, \(c_{\text{curtail}}\) corresponds to curtail_cost_per_mwh. info["cost_sum"] is the sum of the reported cost components.

Cost channel definitions:

Symbol Constraint name Info key Meaning
\(C_{\text{curtail}}\) curtailment cost_curtailment Energy curtailed now times curtail_cost_per_mwh.
\(C_{\text{shift}}\) shift_discomfort cost_shift_discomfort Discomfort cost proportional to deferred energy remaining in the shift buffer.
\(C_{\text{simul}}\) simultaneous_activation cost_simultaneous Penalty for curtailing and shifting load out in the same step.

FlexLoadEnv.step optionally accepts lmp= so the LMP can appear in the observation, but price does not change the physical update. FlexLoadBundle packs n_devices flex loads into batched per-device arrays for use in DSO / DERs.

Bundle observation

Per device, the FlexLoadBundle observation is:

[curtail_norm, shift_out_norm, shift_in_norm, buffer_fill_ratio, buffer_energy_norm]

  • curtail_norm = curtailed_mw / curtail_cap_mw
  • shift_out_norm = shift_out_mw / shift_cap_mw
  • shift_in_norm = shift_in_mw / shift_cap_mw
  • buffer_fill_ratio = buffer_size / shift_horizon
  • buffer_energy_norm = buffered_deferred_energy / (shift_cap_mw * shift_horizon)

The parent grid env appends these slices device-major to build <bundle_obs>. In the DSO benchmark, that produces the flexload_obs (30) tail because there are 6 devices and 5 features per device.

Diesel — DieselBundle

Diesel currently exposes public pure helpers plus a public bundle form, but no standalone DieselEnv.

Action and output

Per device, the action is one scalar in [0, 1]:

\[ P_{\text{dg}} = a \, P_{\max} \]

The bundle also supports an optional minimum-loading rule p_min_norm:

  • below the deadband (p_min_norm / 2): generator stays off
  • above the deadband: output is clamped to at least p_min_norm * p_max

Reactive power is fixed to zero in the current benchmark implementation.

Observation and accounting

Per device, the bundle observation is [p_norm, dg_margin_norm], where:

  • p_norm = p_dg / p_max
  • dg_margin_norm = 1 - p_norm

Reward and cost

  • reward: no standalone diesel reward exists here because diesel is exposed as a bundle
  • cost_info["cost"] = 0.0
  • cost_info["fuel_cost"] and cost_info["carbon_kg"] are reported separately

So diesel does not create a standalone CMDP-cost channel at the resource layer; fuel and carbon are meant to enter the parent env objective explicitly.

Data center — DataCenterEnv

DataCenterEnv is a load-side environment with three coupled layers: IT power, cooling power, and zone thermal dynamics.

State and parameters

classDiagram
    class DataCenterState {
        +t_zone  t_setpoint  t_outdoor
        +p_it_mw  p_cool_mw
        +gpus_infer  gpus_active
        +task_status  sla_violations
        +done
    }
    class DataCenterParams {
        +n_gpus
        +gpu_idle_w  gpu_active_w
        +cop_ref  c_thermal  ua_cooling
        +t_set_min  t_set_max  t_critical
    }

Action

3-D action:

  • action[0]: fraction of currently available GPUs allocated to training jobs
  • action[1]: fraction of the remaining available GPUs allocated to finetuning jobs
  • action[2]: normalized cooling setpoint between t_set_min and t_set_max

Job dynamics

  • training and finetuning arrivals are sampled from Poisson processes
  • new jobs are inserted into a fixed-size waiting queue
  • urgent jobs are force-scheduled first
  • the agent-controlled scheduler allocates the remaining GPUs with an earliest-deadline-first greedy rule, meaning jobs with the closest deadline are considered first
  • waiting jobs that miss their deadline become SLA violations

Power equations

IT and cooling power:

\[ P_{\text{it}} = \frac{P_{\text{infer}} + P_{\text{running}} + P_{\text{idle}}}{10^6} + P_{\text{base}} \]

Unit conversion

The division by 10^6 converts watts to megawatts. Per-GPU quantities such as gpu_idle_w and gpu_active_w are stored in W, so P_infer, P_running, and P_idle are accumulated in W first. The env, however, reports facility-scale active power in MW (p_it_mw, current_p_mw, p_base_mw), so the sum must be divided by 1,000,000 before adding P_base.

\[ \mathrm{COP} = \mathrm{COP}_{\text{ref}}\, \mathrm{clip}\!\left(1 - k_{\text{cop}}\, \max(T_{\text{out}} - T_{\text{ref}}, 0),\ 0.4,\ 1.2\right) \]
\[ Q_{\text{cool}} = UA_{\text{cool}}\, \max(T_{\text{zone}} - T_{\text{set}}, 0) \]
\[ P_{\text{cool}} = \frac{Q_{\text{cool}}}{\mathrm{COP} \cdot 10^3} \]

Zone thermal update:

\[ T_{\text{zone}}^{+} = \mathrm{clip}\!\left(T_{\text{zone}} + \Delta t\, \frac{P_{\text{it,kW}} - Q_{\text{cool}} + Q_{\text{wall}}}{c_{\mathrm{th}}},\ 15,\ 45\right) \]

Total electrical demand:

\[ P_{\text{dc}} = P_{\text{it}} + P_{\text{cool}} + \alpha_{\text{aux}}\, P_{\text{it}} \]

Symbol guide

In the equations above:

  • \(P_{\text{infer}}\): inference GPU power, accumulated in W before the \(10^6\) conversion.
  • \(P_{\text{running}}\): power of GPUs currently running scheduled training / finetuning jobs, in W.
  • \(P_{\text{idle}}\): idle-GPU power for GPUs that are installed but not currently active, in W.
  • \(P_{\text{base}}\): non-GPU base facility load, in MW.
  • \(\mathrm{COP}_{\text{ref}}\): reference coefficient of performance for cooling.
  • \(k_{\text{cop}}\): temperature-sensitivity coefficient that reduces cooling efficiency as outdoor temperature rises above \(T_{\text{ref}}\).
  • \(T_{\text{out}}\): outdoor temperature.
  • \(T_{\text{ref}}\): reference outdoor temperature used by the COP model.
  • \(UA_{\text{cool}}\): effective cooling conductance; it converts the temperature gap \((T_{\text{zone}} - T_{\text{set}})\) into a cooling heat-removal term.
  • \(T_{\text{zone}}\): current zone temperature inside the data center.
  • \(T_{\text{set}}\): cooling setpoint chosen by the agent.
  • \(Q_{\text{cool}}\): cooling heat removed from the zone.
  • \(P_{\text{it,kW}}\): \(P_{\text{it}}\) expressed in kW for the thermal ODE.
  • \(Q_{\text{wall}}\): heat exchange with the outside through the building envelope.
  • \(c_{\mathrm{th}}\): effective thermal capacitance of the zone (the \(\texttt{c\_thermal}\) field, units kWh/°C; lowercase to disambiguate from the cost-vector symbol \(C_{\mathrm{th}}\)).
  • \(\Delta t\): step length in hours (delta_t_hours).
  • \(\alpha_{\text{aux}}\): auxiliary-power fraction applied on top of IT power.
  • \(P_{\text{dc}}\): total data-center electrical demand, in MW.

The env reports current_p_mw = -P_dc_mw.

Reward and cost

The standalone data-center env uses

\[ r_t = 0 \]

and

\[ \text{costs} = (C_{\mathrm{sla}}, C_{\mathrm{ot}}) \]

where:

  • \(C_{\mathrm{sla}}\) is SLA violation density: the number of waiting jobs that have already missed their deadline, divided by \(\texttt{n\_gpus}\).
  • \(C_{\mathrm{ot}}\) is the normalized over-temperature excess (overtemp).

SLA means service-level agreement, here the per-job deadline obligation. info["cost_sum"] is the sum of the reported cost components.

Cost channel definitions:

Symbol Constraint name Info key Meaning
\(C_{\mathrm{sla}}\) sla cost_sla Expired waiting jobs divided by n_gpus.
\(C_{\mathrm{ot}}\) overtemp cost_overtemp Normalized excess of zone temperature above the critical threshold.

Why a separate microgrid env exists

DataCenterEnv models a grid-connected data-center load. To benchmark a self-contained microgrid that combines this load with PV, battery, and diesel, use DataCenterMicrogridEnv; see Microgrid.

Where these resources appear

Task / env Resource use
DSO benchmark FlexLoadBundle
DERs benchmark BatteryBundle + RenewableBundle + FlexLoadBundle
Market envs BatteryBundle
Data-center microgrid DataCenterEnv composed with battery / PV / diesel logic